CN

Wall mounted passive laser monitoring system

Technical Consulting
Technical Advisory Services
In order to better understand the needs of the enterprise, I hope you fill in the following information form, and the professional technical sales of Hanhai Technology will contact you in time after submission.

Institution Name *

Purchase quantity

Needs and suggestions

Basic Information *

Product Description

The wall mounted passive laser monitoring system is particularly suitable for underground insulation head gas leakage monitoring of gas pipelines entering and leaving unmanned stations. The system consists of a wall mounted host, a photosensitive terminal, an expansion module, and a management platform. The light sensing terminal is a passive device that can be buried underground simultaneously with the pipeline, achieving long-term online monitoring of insulation joint leakage. A wall mounted device can carry 2 or 16 photosensitive terminals through expansion modules. Different light sensing terminals can be configured according to different scenarios.

  • Independent research and development

  • Active monitoring

  • Maintenance-free

  • High sensitivity

  • No false positives

  • Zero false negatives

  • Strong anti-interference

  • Application Scenarios

    Suitable for underground insulation head gas leakage monitoring of gas pipelines entering and exiting unmanned stations.

    The main function

    The sensor host integrates laser information transmission and reception, making the overall size smaller and allowing for free placement, making it easier to install and move.

    Each monitoring channel has a response time of only 10 seconds and can accurately detect ppm level trace gas leaks, truly achieving gas leak prevention monitoring.

    Mainly used for buried insulation joints, supporting real-time multi-channel transmission (up to 16 channels).

    Real time monitoring of the site and display of monitoring data.

    Light sensing terminals are pure optical devices with lossless characteristics. High reliability, no need for calibration.

    Ultra long system operating life. Significantly reduce the operating costs of equipment throughout its lifecycle, once and for all.

    Contact Us

    TEL:400-055-1239 (9:00~17:00)

    MAIL:lisghanhai@gkhhlaser.com

    ADDR:302 Floor, Building 5, No. 18, Kechuang 13th Street, Beijing Economic and Technological Development Zone

    Follow Us

  • 官方微信

    WeChat

  • ICP:皖ICP备14011335号-1 COPYRIGHT © Guoke Hanhai Laser Technology(Beijing)Co.,Ltd ALL RIGHTS RESERVED.